HPLC Column, RP C8 Octyl, 5um, 2.1mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C8™ HPLC Columns are designed for reliable reversed-phase chromatography using a traditional octyl (C8) bonded stationary phase. Manufactured with ultra-high purity silica and fully double end capped bonding technology, these columns provide reproducible retention, excellent peak shape, and long column life. The RP C8™ phase is a USP L7 equivalent chemistry and is commonly used as an alternative for methods developed on similar C8 phases. Compared to C18 columns, RP C8™ generally provides lower hydrophobic retention while maintaining excellent selectivity for many neutral and non-polar compounds.
68508-10P-2 is packed with 5 µm RP C8™ particles featuring a 100 Å pore size in a 2.1 mm ID x 100 mm length format. The 100 mm column length provides increased resolving power compared to shorter 50 mm columns while maintaining reasonable analysis times. The RP C8™ stationary phase is well suited for hydrophobic compounds, neutral analytes, and long-chain fatty acids where somewhat lower retention than a comparable C18 column is desired. The 5 µm particle size provides low backpressure and broad compatibility with conventional HPLC and LC-MS systems.
This column is frequently selected for LC-MS applications when greater chromatographic resolution is required without moving to longer analytical columns. The 2.1 mm ID format minimizes solvent consumption and is particularly suited for mass spectrometry workflows. Optimum performance is typically achieved at approximately 0.2-0.3 mL/min. Standard HPLC systems used with this column must be capable of delivering accurate and reproducible low flow rates, and low-volume detector flow cells are recommended to minimize extra-column band broadening.
Key Benefits
RP C8™ stationary phase
USP L7 equivalent chemistry
Octyl (C8) bonded phase
Fully double end capped
Ultra-high purity silica support
100 Å pore size
Increased resolution compared to 50 mm columns
Lower retention than C18 phases
Reduced solvent consumption
Excellent for LC-MS applications
Typical Applications
Reversed-phase HPLC
LC-MS analysis
Method development
Pharmaceutical analysis
Long-chain fatty acid analysis
Hydrophobic compound separations
Neutral compound analysis
Environmental testing
Bioanalytical methods
Routine quality control
Specifications
Product Type: HPLC Column
Stationary Phase: RP C8™
USP Classification: L7
Chromatography Mode: Reversed Phase
Bonded Phase: Octyl (C8)
Endcapping: Fully Double End Capped
Particle Size: 5 µm
Pore Size: 100 Å
Column Dimensions: 2.1 mm ID x 100 mm
Recommended Flow Rate: 0.2-0.3 mL/min
Column Hardware: Stainless Steel
Brand: Cogent
Important Notes
Designed for reversed-phase HPLC and LC-MS applications requiring increased resolution
Provides lower retention than comparable C18 columns
Suitable for hydrophobic and moderately non-polar compounds
Excellent choice for long-chain fatty acid separations
100 mm length provides greater resolving power than shorter analytical columns
5 µm particles provide low backpressure and broad instrument compatibility
Requires an HPLC system capable of precise and reliable low flow rate delivery
Low-volume detector flow cells are recommended to maximize efficiency
Reduces solvent consumption compared to standard 4.6 mm ID columns
Manufactured using ultra-high purity silica and fully double end capped bonding technology